Appendix A Slammer LED Startup Progress Codes

Slammer LED Startup and Halt Codes

The following table describes the meaning of the Slammer startup and halt codes
as indicated by the LEDs.
The system may go through this sequence more than once if the network is
having trouble responding.

Table 27 Slammer LED boot block status codes

Code
FLT
ACT
Off
Off
Off
Orange
Off
Green
On
Green
Off
Rapid orange
Off
Green
Off
Slow orange
Off
Rapid green
Off
Slow green
Off
Green
Slammer LED Startup and Halt Codes
Software module
ST
Rapid green
EEL_BOARD_INIT_0
Rapid green
EEL_BOARD_INIT_1
Rapid green
EEL_BOARD_INIT_2
Rapid orange
EEL_MEM_INIT
Rapid green
EEL_BOARD_INIT_4
Slow orange
EEL_MEM_READY
Rapid green
EEL_BOARD_INIT_6
Rapid green
EEL_BOARD_INIT_8
Rapid green
EEL_BOARD_INIT_10
Green
EEL_RAM_LOADER
Meaning
Clean progress to
BoardInit0.
Clean progress to
BoardInit1.
Clean progress to
BoardInit2.
Memory training has begun.
Clean progress to
BoardInit4.
Memory training has
completed.
Clean progress to
BoardInit6.
Clean progress to
BoardInit8.
Clean progress to
BoardInit10.
Clean progress to RAM
loader.