Figure 7 Rack Leveling Leg Locations; Figure 8 Leveling Leg Adjustment - Oracle Pillar Axiom 600 Hardware Installation Manual

Oracle pillar axiom 600 hardware installation guide
Table of Contents

Advertisement

Chapter 2 Set Up the Rack
1 Turn each leveling leg clockwise to lower the feet until they touch the floor.
Use a 1/4-inches (7-millimeters) flat-tip screwdriver in the slot at the top of
the leg.

Figure 7 Rack leveling leg locations

Legend
2 Use a 3/4-inches (19-millimeters) open-end wrench on the bottom of the
legs to jack up the rack. Raise the rack until it is level with all the casters off
the floor.

Figure 8 Leveling leg adjustment

Legend
Rack Position
1 Caster brackets
2 Leveling legs are pre-installed in each caster bracket.
1 Caster brackets
2 Slot in the leveling leg for a screwdriver