3 On the Bricks, verify:
Verify the Back Status LEDs
● The thumb-wheel on the Enclosure Services (ES) module is set to 0
for the following Brick types: Serial ATA (SATA), SATA Version 2,
solid state drives (SSD), and Fibre Channel RAID (FC RAID).
● The thumb-wheel on the ES module is set to 1 for all FC Expansion
(FCE) Bricks.
● The power supply LEDs are green and not blinking.

Figure 64 Brick LEDs

Legend
1 RAID controller LEDs (SATA)
2 Power supply LED
3 ES module LED
4 Spare drive LEDs
Note: This image is for illustration purposes only. Your hardware
component might look different.
If either power supply LED is amber or turned off:
○ Ensure the power cable on that side is securely connected at
both ends.
○ Ensure the PDU and Brick are powered on.
● The ES module LED is green and not blinking. If the ES module LED
is amber, ensure that both power cables are securely connected to
both the Brick and the PDU.
● The RAID controller LEDs are green. If the RAID controller LEDs are
off or are blinking green, check the network connections.
● The spare drive LEDs are green and not blinking.
Note: If the ES module, RAID controller, or spare drive has failed,
contact the Pillar World Wide Customer Support Center.