Download Print this page
IBM EMX0 PCIe Gen3 Manual

IBM EMX0 PCIe Gen3 Manual

Expansion drawer cable for expansion drawer
Hide thumbs Also See for EMX0 PCIe Gen3:

Advertisement

Quick Links

Power Systems
Expansion drawer cable for the EMX0
PCIe Gen3 I/O expansion drawer
IBM

Advertisement

loading
Need help?

Need help?

Do you have a question about the EMX0 PCIe Gen3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IBM EMX0 PCIe Gen3

  • Page 1 Power Systems Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer...
  • Page 3 Power Systems Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer...
  • Page 4 Note Before using this information and the product it supports, read the information in “Safety notices” on page v, “Notices” on page 21, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. ™...
  • Page 5: Table Of Contents

    Safety notices ....... . . v Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer ..1 Removing and replacing an expansion drawer cable in the EMX0 PCIe3 expansion drawer .
  • Page 6 Power Systems: Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer...
  • Page 7: Safety Notices

    Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v If IBM supplied the power cord(s), connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product.
  • Page 8 In addition, do not lean on rack mounted devices and do not use them to stabilize your body position (for example, when working from a ladder). Power Systems: Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer...
  • Page 9 v Each rack cabinet might have more than one power cord. – For AC powered racks, be sure to disconnect all power cords in the rack cabinet when directed to disconnect power during servicing. – For racks with a DC power distribution panel (PDP), turn off the circuit breaker that controls the power to the system unit(s), or disconnect the customer’s DC power source, when directed to disconnect power during servicing.
  • Page 10 DANGER: Hazardous voltage, current, or energy levels are present inside any component that has this label attached. Do not open any cover or barrier that contains this label. (L001) (L002) viii Power Systems: Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer...
  • Page 11 DANGER: Rack-mounted devices are not to be used as shelves or work spaces. (L002) (L003) Safety notices...
  • Page 12 DANGER: Multiple power cords. The product might be equipped with multiple AC power cords or multiple DC power cables. To remove all hazardous voltages, disconnect all power cords and power cables. (L003) (L007) CAUTION: A hot surface nearby. (L007) (L008) Power Systems: Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer...
  • Page 13 Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call. (C003)
  • Page 14 Power and cabling information for NEBS (Network Equipment-Building System) GR-1089-CORE The following comments apply to the IBM servers that have been designated as conforming to NEBS (Network Equipment-Building System) GR-1089-CORE: Power Systems: Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer...
  • Page 15 The equipment is suitable for installation in the following: v Network telecommunications facilities v Locations where the NEC (National Electrical Code) applies The intrabuilding ports of this equipment are suitable for connection to intrabuilding or unexposed wiring or cabling only. The intrabuilding ports of this equipment must not be metallically connected to the interfaces that connect to the OSP (outside plant) or its wiring.
  • Page 16 Power Systems: Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer...
  • Page 17: Expansion Drawer Cable For The Emx0 Pcie Gen3 I/O Expansion Drawer

    Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer Find information about removing and replacing the expansion drawer cable that connects the EMX0 PCIe Gen3 I/O expansion drawer (EMX0 PCIe3 expansion drawer) to your server. Removing and replacing an expansion drawer cable in the EMX0 PCIe3...
  • Page 18 Pull out the quarter-turn fasteners (B) and turn them to disengage them while you lift the cable management bracket (A) to its raised position. b. Turn the quarter-turn fasteners (B) to engage and lock the bracket into position. Power Systems: Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer...
  • Page 19: Removing An Expansion Drawer Cable From The Emx0 Pcie3 Expansion Drawer

    Figure 2. Placing the cable management bracket in the raised service position Removing an expansion drawer cable from the EMX0 PCIe3 expansion drawer To remove an expansion drawer cable from the EMX0 PCIe3 expansion drawer, complete the steps in this procedure.
  • Page 20: Replacing An Expansion Drawer Cable In The Emx0 Pcie3 Expansion Drawer

    Replacing an expansion drawer cable in the EMX0 PCIe3 expansion drawer To replace an expansion drawer cable in the EMX0 PCIe3 expansion drawer, complete the steps in this procedure. Power Systems: Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer...
  • Page 21: About This Task

    About this task Important: To avoid damage to the connectors on the expansion drawer cable, do not remove the protective covers until just before you need to plug the cable into the host system or EMX0 PCIe3 expansion drawer. Procedure 1.
  • Page 22: Preparing The Emx0 Pcie3 Expansion Drawer For Operation After Removing And Replacing An Expansion Drawer Cable

    To prepare the EMX0 PCIe3 expansion drawer for operation after removing and replacing an expansion drawer cable, complete the steps in this procedure. Power Systems: Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer...
  • Page 23 Procedure 1. Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged into a ground jack or connected to an unpainted metal surface. If not, do so now. 2. Route the cables through the cable management bracket, while in the service position. 3.
  • Page 24 Figure 9. Rear power indicator for the EMX0 PCIe3 expansion drawer Power Systems: Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer...
  • Page 25: Common Procedures For Removing Or Replacing An Expansion Drawer Cable

    Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v If IBM supplied the power cord(s), connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product.
  • Page 26 It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock. (R001 part 2 of 2): CAUTION: Power Systems: Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer...
  • Page 27 If you are installing a feature, contact one of the following service organizations: – The provider of your parts or next level of support. – In the United States, the IBM Rochester Manufacturing Automated Information Line (R-MAIL) at 1-800-300-8751.
  • Page 28: Control Panel Leds

    If you remove, then re-install an electronic component, temporarily place that component on an ESD mat. 9. If you encounter difficulties during the installation, contact your service provider, your IBM reseller, or your next level of support.
  • Page 29: Enabling Enclosure Or Server Indicators By Using The Asmi

    Enabling enclosure or server indicators by using the ASMI Find out how to enable enclosure or server indicators by using the Advanced System Management Interface (ASMI). About this task To perform this operation, you must have one of the following authority levels: v Administrator v Authorized service provider To enable the enclosure or server indicator states, complete the following steps:...
  • Page 30: Starting A System By Using The Asmi

    2. Select the system that you want to power on. 3. In the content pane, click Actions > View All Actions > Power On. 4. Click Finish. Power Systems: Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer...
  • Page 31: Stopping A System

    v To activate a logical partition, complete the following steps: 1. In the navigation area, click the Resources icon , and then click All Partitions. 2. Click the logical partition name that you want to activate. 3. In the navigation area, click Partition Actions > Operations > Activate. 4.
  • Page 32: Stopping A System By Using The Control Panel

    If your system is running the Linux operating system, type shutdown -h now. v If your system is running the IBM i operating system, type PWRDWNSYS. If your system is partitioned, use the PWRDWNSYS command to power off each of the secondary partitions. Then, use the PWRDWNSYS command to power off the primary partition.
  • Page 33: Installing Or Replacing A Part By Using An Hmc

    v Product engineer Note: If you are a product engineer, verify that the customer has shut down all active partitions and has powered off the managed system. Continue with the procedure only after the status of the server changes to Power Off. Procedure 1.
  • Page 34: Removing A Part By Using The Hmc

    8. After the part is listed in the Pending Actions section, click Launch Procedure and follow the instructions to remove the part. Note: The HMC might display the IBM Knowledge Center instructions for removing the part. If so, follow those instructions to remove the part.
  • Page 35 7. Select a serviceable event and use the Selected drop-down menu list to select Repair. 8. Follow the instructions to repair the part. Note: The HMC might open IBM Knowledge Center instructions for repairing the part. If so, follow those instructions to repair the part.
  • Page 36 Power Systems: Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer...
  • Page 37: Notices

    Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
  • Page 38: Homologation Statement

    All IBM prices shown are IBM's suggested retail prices, are current and are subject to change without notice. Dealer prices may vary. This information is for planning purposes only. The information herein is subject to change before the products described become available.
  • Page 39: Privacy Policy Considerations

    This product uses standard navigation keys. Interface information The IBM Power Systems servers user interfaces do not have content that flashes 2 - 55 times per second. The IBM Power Systems servers web user interface relies on cascading style sheets to render content properly and to provide a usable experience.
  • Page 40: Trademarks

    IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the web at Copyright and trademark information at www.ibm.com/legal/copytrade.shtml.
  • Page 41: Vcci Statement (Japan)

    Warning: This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. VCCI Statement - Japan The following is a summary of the VCCI Japanese statement in the box above: This is a Class A product based on the standard of the VCCI Council.
  • Page 42: Electromagnetic Interference (Emi) Statement - Taiwan

    Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user will be required to take adequate measures. IBM Taiwan Contact Information: Power Systems: Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer...
  • Page 43: Germany Compliance Statement

    Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 44: Class B Notices

    Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by unauthorized changes or modifications to this equipment.
  • Page 45 European Community contact: IBM Deutschland GmbH Technical Regulations, Abteilung M456 IBM-Allee 1, 71139 Ehningen, Germany Tel: +49 800 225 5426 email: halloibm@de.ibm.com VCCI Statement - Japan Japan Electronics and Information Technology Industries Association Statement This statement explains the Japan JIS C 61000-3-2 product wattage compliance.
  • Page 46 Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 47: Terms And Conditions

    Permissions for the use of these publications are granted subject to the following terms and conditions. Applicability: These terms and conditions are in addition to any terms of use for the IBM website. Personal Use: You may reproduce these publications for your personal, noncommercial use provided that all proprietary notices are preserved.
  • Page 48 Power Systems: Expansion drawer cable for the EMX0 PCIe Gen3 I/O expansion drawer...
  • Page 50 IBM®...