Configuring Remote Control Button Circuits (Is4, Is10, Spacommand, Spa Side Remtoe, Qt4 Quicktouch, And Phone Remote) - Intellitouch User Manual

Pool and spa control system
Table of Contents

Advertisement

Configuring Remote Control Button Circuits
(iS4, iS10, SpaCommand Spa Side Remote,
QuickTouch (QT4) and phone remote)
From the spa side remote screen you can configure the iS4, iS10 and
SpaCommand
buttons to control different pool/spa functions, including
IntelliFlo VF 3050, VS 3050 and VSF+SVRS pump speeds. Up to two iS4
remotes, and four iS10 and SpaCommand remotes can be connected to an
IntelliTouch system. To assign a circuits to spa-side remote buttons:
1. Press the button next to
CONFIGURE 10 BUTTON SS's or CONFIGURE QUICKTOUCH
to select the remote.
For iS4: Press the top button to access the setup screen for iS4 #1 and
iS4 #2 . See note below if multiple iS4 remotes are installed.
For iS10 and SpaCommand: Press top button to select 10 BUTTON
SPA SIDE #1 for the first iS10 or SpaCommand remote. Choose which
one of the four remotes you are configuring, 10 BUTTON SPA SIDE #1
#2, #3 or #4. See note below if multiple iS10 or SpaCommand remotes
are installed.
For QuickTouch: Press the button next "CONFIGURE
QUICKTOUCH"
to access the setup screen.
2. On the next screen: Press the button next to the circuit you wish to
assign. A small arrow is displayed pointing to the name of that circuit. Use
the Up and Down buttons at the bottom of the screen to scroll through the
iS10 or iS4 circuit names (SPA, POOL, AUX 1-8, HEAT BOOST,
HEAT ENABLE, INCREASE PMP SPD, DECREASE PMP SPD,
NONE). For QuickTouch: (SPA, POOL, AUX 1-4, POOL). Note:
When assigning buttons to "Increase" and "Decrease" the
IntelliFlo VF (GPM), VS (RPM) and VSF+SVRS (RPM/GPM).
Each press of the assigned button increases or decreases the
pump's "step" flow rate or speed until the GPM or RPM is reached
as specified in the "SPA SIDE INFLO CONTROL" screen
(on the 10 Button SS screen). Be sure to set the
pump address number (in the IntelliFlo screen) for the pump you
wish to control.
3. Continue the process to assign other circuits to the spa-side control
buttons. Press the Save button to save the settings and return to the
previous screen. Press the Exit button to return to the main screen. Press
Back to go back to the remotes screen to configure another remote.
Note: For systems with four iS10/SpaCommand remotes, adding one or two iS4
remotes will affect button function assignments as follows: Assigned button
functions 1 - 4 on iS4 #1 are linked with the same functions to buttons 1 - 4 (top row) of
iS10 #4. Also, buttons 1 - 4 on iS4 #2 are linked to buttons 6 - 10 (bottom row) of iS10
#4. For example, button 6 on the bottom row of iS10 #4 is linked to button 1 of iS4 #2,
button 7 on iS10 #4 is linked to button 2 of iS4 #2, etc.
CONFIGURE iS4'S or
iS4 spa side remote
iS4 circuit/button setup
INC PMP SPD
DEC PMP SPD
iS10 circuit/button setup
INTELLIFLO PUMP # 1
STEP SIZE
SPA SIDE IFLO CONTROL
IntelliTouch Pool and Spa Control System User's Guide
81
LED
10 GPM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pool and spa control system

Table of Contents