Assign Circuit Functions and Freeze Protection

Assigning a function to an auxiliary circuit allows certain type of equipment to operate in a specific way. For
example, when setting up an automatic pool cleaner pump, you would assign the circuit function to MASTER
CLEANER. With this "Cleaner" logic, when the circuit is switched on the cleaner pump would force the filter
pump on, and start the cleaner pump after a delay of five (5) minutes. The cleaner pump would automatically
shut off whenever the spa and solar is switched on with the cleaner pump (after a delay of five (5) minutes) if
energy from the solar is required.

Freeze Protection

Freeze protection switches a circuit on if the outdoor air temperature sensor detects the temperature is getting
close to freezing (below 36° F (2 ° C). The system switches on all circuits that have been assigned freeze
protection, and switches on the filter pump to circulate water throughout the system for 15 minutes to stop the
pipes from freezing. This is especially important for a pool and spa combination (dual body shared equipment).
If freeze protection is set to both the spa and pool circuits, the filter pump switches on and the pool and spa
valves alternate every 15 minutes to keep the water moving through both the pool and spa. This process
continues until the freeze condition is over.

Assigning a function and freeze protection to a circuit

Getting There
MENU SETUP ADVANCED CIRCUIT FUNCTIONS
To assign a function to an auxiliary circuit and to add circuit freeze protection:
1. Press the button next to the circuit name that requires a function.
2. Press the lower DISPLAY button to view the Feature circuits.
Select the Feature circuit name to assign a function to it. Use this
button to toggle between the Feature circuit screen and the Circuit
screen.
This Button appears only
when you have FEATURE
circuits or multiple DISPLAYS.
SELECT DESIRED SCREEN
DISPLAY 1,2,3,4 or F
IntelliTouch Pool and Spa Control System User's Guide
SELECT DESIRED CIRCUIT
AUX 5
FLOOR CLNR
FOUNTAIN
AUX 6
AUX 2
AUX 7
AUX 4
AUX 8
1
MENU/SETUP/ADV/FUNCTION/SELECT
DISPLAY
BACK
EXIT
CLEANERS
EDGE PUMP
ALL LIGHTS
WATER FALL
MON 4:32AM
F
AIR TEMP 92˚
MENU
HEAT
LIGHTS
DISPLAY
39