Intellitouch User Manual page 8

Pool and spa control system
Table of Contents

Advertisement

vi
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
IMPORTANT
FCC Regulatory Safety Notice - The MobileTouch wireless control panel device has been tested and found
to comply with the liFCC Standard - 47 CFR Part 15, Subpart C (Section 15.247). This version is limited to
chapter 1 to chapter 11 by specified firmware controlled in the U.S.A.
Canada - Industry Canada (IC) - The IntelliChlor device complies with RSS210 of Industry Canada. (1999).
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this
device must accept any interference, including interference that may cause undesired operation of the device.
Instruction to user - The IntelliChlor device has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. The IntelliChlor device generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this device does cause harmful interference to radio or television reception, which can
be determined by switching the device off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
General Installation Information
1. All work on the IntelliTouch® load/power center must be performed by a licensed electrician, and must
conform to all national, state, and local codes.
2. Install to provide drainage of compartment for electrical components.
3. If this system is used to control underwater lighting fixtures, a ground-fault interrupter (GFCI) must be
provided for these fixtures. Conductors on the load side of the ground-fault circuit-interrupter shall not
occupy conduit, junction boxes or enclosures containing other conductors unless such conductors are
also protected by a ground-fault circuit-interrupter. Refer to local codes for details.
4. A terminal bar stamped
shock, this terminal must be connected to the grounding means provided in the electric supply service
panel with a continuous copper wire equivalent in size to the circuit conductors supplying this
equipment (no smaller than 12 AWG or 3.3 mm). The bonding lug(s) provided on this unit are intended
to connect a minimum of one No. 8 AWG for US installation and two No. 6 AWG for Canadian
installations solid copper conductor between this unit and any metal equipment, metal enclosures or
electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit.
5. The electrical supply for the IntelliTouch® load/power center must include a suitably rated switch or
circuit breaker to open all ungrounded supply conductors to comply with in accordance with the
National Electrical Code (NEC), NFPA 70 or the Canadian Electrical Code (CEC), CSA C22.1. All
applicable local installation codes and ordinances must also be adhered to. The disconnecting means
must be readily accessible to the tub occupant but installed at least 10 ft. (3.05 m) from the inside wall
of the pool.
6. GAS HEATER: The IntelliTouch® automation control system is designed to supply high voltage (120
VAC / 240 VAC) to a gas heater and override the thermostat in the heater's control circuit. This
automation control system is intended to control gas heaters with a high temperature limit switch(s)
safety circuit ONLY. Failure to do so may cause property damage or personal injury.
6. Supply conductor for the IntelliTouch® load/power center must be sized to support all loads. Maximum
supply conductor current must be 150 Amps at 120 VAC / 240 VAC.
For information about the Virginia Graeme Baker Pool and Spa Safety Act, contact the Consumer Product Safety
Commission at (301) 504-7908 or visit www.cpsc.gov.
NOTE: Always turn off all power to the pool pump before installing the cover or working on any suction outlet.
IntelliTouch Pool and Spa Control System User's Guide
WARNINGS
( C O N T I N U E D )
is located inside the supply terminal box. To reduce the risk of electric
AND
SAFETY
PRECAUTIONS

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pool and spa control system

Table of Contents