Master Spa/Pool (Heater Cool-Down) and Delays For Valves
Go to the Pump Delays screen.
Getting There
MENU SETUP
EQUIPMENT
1. Press the button next to Master Spa/Pool. Press the left or
right side button change the setting to Yes. Note: Pentair
Water Pool and Spa
2. Press the button next to Delay For Valves. Press the left or
right side button change the setting to Yes.
3. Press the Save button.
4. Press the Exit button to return to the main screen.

Delay Cancel Feature

For convenience, on a one time basis, the DELAY CANCEL feature will cancel the following safety delays
which can be set up in the IntelliTouch system. Please note there is generally not a need to cancel any of these
delays except for servicing or testing the system.
Heater Cool-Down Delay Cancel: Shuts Filter Pump off immediately.
2-Speed Filter Pump 5 minute START on HIGH SPEED Delay Cancel: Shifts pump to low speed.
Automatic Pool Cleaner START Delay: Starts Cleaner Pump immediately. Normally there is a delay in
which the filter pump first runs for 5 minutes before the cleaner pump starts.
Automatic Pool Cleaner-SOLAR Delay: Allows Cleaner Pump to run even though solar delay has shut it
off for 5 minutes.
About the Heater Cool-down Cycle and Delay Cancel
Some heaters require a cool-down cycle before being turned off. This can be accomplished with a SET UP
procedure in the IntelliTouch system which runs the filter pump an additional ten minutes to dissipate residual
heat built up inside the heater combustion chamber. The DELAY CANCEL feature is mainly for use by service
technicians when they want to shut the filter pump off immediately, and know the heater has not been running.
IMPORTANT: Heaters manufactured by Pentair Water Pool and Spa
and do not need the delay to be set up.
To cancel a safety delay:
Getting There
MENU DELAY CANCEL
Go to Delay Cancel Screen
1. Press the button next to DELAY CANCEL. Equipment is
switched off and ready to be serviced.
2. Press the Back button when finished. The system delay is
disabled and the system is returned to normal operating mode.
IntelliTouch Pool and Spa Control System User's Guide
PUMP DELAYS
®
heaters do not require this feature.
DELAY FOR VALVES
MENU/SETUP/EQUIPMENT/PUMP DELAYS
®
do not require this cool-down period