IntelliFlo VS 3050 and VSF+SVRS Pump Setup
Assign custom speeds (RPM) IntelliFlo VS 3050 pump
Each Intelliflo VS 3050 pump can have a maximum of eight assigned circuits with eight preset pump speeds
(RPM). The speeds can be set from 400 RPM to 3450 RPM.
Getting There
MENU SETUP EQUIPMENT INTELLIFLO
To set the IntelliFlo VS 3050 pump speed to an assigned circuit name:
1. From the main pump screen, press the left side button next to the selected IntelliFlo VS 3050 pump.
Note: An IntelliFlo VS 3050 pump can only be assigned as pump #1, #2, #3, or #4.
2. On the next screen, press the left side button next to ASSIGN CUSTOM SPEEDS.
Select the
IntelliFlo VS
3050 pump
3. From the next screen you can assign a circuit name and set the pump speed. To assign a circuit name,
press one of the left side buttons next to "NONE." Press the PREV or NEXT lower button to select a
circuit name for the pump. The selected circuit name must also be assigned a circuit function. For details
about assigning a circuit function, see page 39. Press the corresponding RPM button on the right side to
set the speed. Use the DOWN and UP lower buttons to adjust the speed from 400 RPM to 3450 RPM.
Press this
button to
assign a
circuit name
4. Press the lower SAVE button to save the circuit and speed setting. To set another circuit and pump
speed, press the button next to ASSIGN CUSTOM SPEEDS to access the circuit and speed setup
screen. If you need additional pump speed circuits, press the button next to NEXT PAGE to access an
additional four circuits, then repeat step 3.
5. When finished, press the BACK button to return to the Equipment screen.
IntelliTouch Pool and Spa Control System User's Guide
IFLO VF 3050
#1
POOL
IFLO VS 3050
#2
SPA
IFLO VSF+SVRS #3
IFLO VS 3050
#4
AUX 3
NEXT GROUP OF PUMPS
MENU/SETP/EQUIP/IFLO/SELECT
BACK
EXIT
AUX 4
750 RPM
AUX 5
1500 RPM
AUX 6
2350 RPM
NONE
1000 RPM
NEXT PAGE
MENU/SETP/EQUIP/INTELLIFLO/ASSIGN
BACK
PREV
NEXT
Prev and Next buttons
(use to assign a circuit name)
(Continued)
Press this
button to
access the
custom speed
screen
AUX 4
750 RPM
AUX 5
1500 RPM
AUX 6
2350 RPM
NONE
1000 RPM
NEXT PAGE
MENU/SETP/EQUIP/INTELLIFLO/ASSIGN
BACK
DOWN
UP
Down and Up buttons
(use to adjust pump speed)
PENTAIR IFLO VS 3050
IFLO VS 3050
#4
SPA
PRIMING PARAMETERS
ASSIGN CUSTOM SPEEDS
INTELLIFLO STATUS
MENU/SETP/EQUIP/INTELLIFLO
BACK
EXIT
Press this
button to
set the
pump
speed