Setting Up An Ultratemp Heat Pump; Ultratemp Heat Pump Screen (Heatpumpcom) - Intellitouch User Manual

Pool and spa control system
Table of Contents

Advertisement

72

Setting up an UltraTemp Heat Pump

UltraTemp heat pump screen (HEAT PUMP COM)
From the HEATPUMPCOM screen you can view the current heat pump operation status, and set the unit to
operate with for heating only, cooling only or both heating and cooling if the unit is reversible. Connection from
the Pentair UltraTemp heat pump to the IntelliTouch system is via an RS-485 communication cable to a COM
PORT on the IntelliTouch Personality circuit board. See page 112 for UltraTemp to IntelliTouch COM port
wiring information. The UltraTemp heatpump must be set to default ADDRESS 1. One UltraTemp unit can be
connected to an IntelliTouch system.
Operating UltraTemp
The UltraTemp heat pump is reversible, meaning it can heat or cool. When cooling is selected, an option heat
control is displayed in the HEAT screen below the pool heat settings labeled as POOL MAX. This setting
allows you to set the maximum heat temperature setting for the pool before the UltraTemp cooling begins.
Getting There
MENU SETUP
EQUIPMENT HEATPUMPCOM
To access the UltraTemp heat pump communication screen:
1. From the EQUIPMENT screen, press the left side button next to HEATPUMPCOM.
2. On the next screen, press the left or right side button to set the heat pump options. To enable the heat pump,
select YES for HEATPUMPCOM PRESENT, HEATPUMPCOM HEATING (use heating only), and
HEATPUMPCOM COOLING (If the unit is reversible select YES to enable the cooling feature, or just
cooling only).
PRIORITY
CHLORINATOR
INTELLIFLO
HEATPUMPCOM
MENU / SETUP /EQUIP
BACK
Decrease temperature
for UltraTemp
heat pump
IntelliTouch Pool and Spa Control System User's Guide
HEATPUMPCOM unit present (Yes/No)
SOLAR
HEATPUMPCOM heating (Yes/No)
2-SPEED PMP
HEATPUMPCOM cooling (Yes/No)
PUMP DELAYS
SPA OPTIONS
DEGREES C/F
EXIT
POOL 85˚
SPA
POOL 100˚
DOWN
POOL MAX 103˚
UltraTemp heat settings
View current heat pump status
HEAT PUMP
HEATER
Increase temperature for
UP
UltraTemp heat pump
YES
HEATPUMPCOM PRESENT
YES
HEATPUMPCOM HEATING
YES
HEATPUMPCOM COOLING
OPERATION NORMAL
MENU/SETP/EQUIPT/HEATPUMPCOM
BACK
NEXT