Intelliflo Menu Options; Intelliflo Pump Type And Assignment Screens - Intellitouch User Manual

Pool and spa control system
Table of Contents

Advertisement

IntelliFlo menu options

To access the following IntelliFlo screens, press
IntelliFlo main pump screens: Two status screens (pumps 1-4, pumps 5-8), each displaying the IntelliFlo
pump number assignments and assigned circuit name for each pump
IntelliFlo VF 3050 Set Parameters screen (page 58-65): From these screens you can set up the pump
parameters (filtering, priming, backwash, vacuum), assign a circuit name, assign up eight pump flows (GPM),
or view the current pump status
IntelliFlo main pump screen (assign pump type, circuit, address)
From these screens you can assign the pump type, circuit name and address for each pump.
Getting There
MENU SETUP EQUIPMENT INTELLIFLO
To access the pump
NOTE: INTELLIFLO AND CLEANER INTERLOCK: In order to safguard the IntelliFlo pump and other
equipment such as a pressure side cleaner booster pump, IntelliTouch monitors the main pump (if it is an
IntelliFlo). If the pump stops, IntelliTouch will delay the cleaner function. This may take as much as 30 seconds.
IntelliTouch will hold the cleaner off until the pump is running again. When the pump is running again IntelliTouch
will restart the cleaner delay, as if it was just starting to insure water in the plumbing.
IntelliTouch requires a bit more delay since the circulation pump may be on any address, e.g. #5, if there are
four IntelliFlo VS pumps at 1 -4, and a VF at #5. So by default no pump is assigned. When you go into the menu
"Circuit Functions" (see page 39, Menu>Setup>Advanced>Circuit Functions), if you assign a circuit as "Master
Cleaner" an extra line will appear at the bottom of the screen. You can then select NONE if you don't have or
want an IntelliFlo interlocked, or numbers 1 - 8 to identify the main circulation pump.
NOTE: INTELLIFLO "FREEZE" PROTECTION - If the IntelliFlo pump is on due to a freeze condition (not
switch on from a relay circuit state), and if a freeze speed/flow is set in IntelliTouch, this setting takes priority
even if the previous setting is lower than the default circuit speed. If no "freeze" protection is set, the pump will
be forced on at the default circuit speed/flow. Any programmed or manual operation that actually switches on a
circuit, will cause the pump to run at that speed if it is higher.
NOTE: INTELLIFLO IN "SERVICE MODE" - The IntelliFlo pump will STOP
when IntelliTouch is in 'Service" mode. The pump will not stop if the communication cable is not connected or
due to the pump's firmware.
NOTE: INTELLIFLO VF PUMPS - If the IntelliFlo VF pump is just starting (requiring a prime) and SOLAR is
available, solar will be delayed for five (5) minutes to allow the pump to prime. This only applies for IntelliFlo
pump(s) assigned as to a "pool" pump.
parameters, press
selected pump
button (1-4)
Press this
button to view
pumps 5-8
MENU > SETUP >EQUIPMENT > INTELLIFLO
IFLO VF 3050
#1
POOL
IFLO VS 3050
#2
SPA
IFLO VSF+SVRS #3
IFLO VS 3050
#4
AUX 3
NEXT GROUP OF PUMPS
MENU/SETP/EQUIP/IFLO/SELECT
BACK
EXIT
IntelliTouch Pool and Spa Control System User's Guide
57
:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pool and spa control system

Table of Contents