Setting Up A 2-Speed Pump; Delay For Valves And Pumps (Heater Cool-Down Cycle) - Intellitouch User Manual

Pool and spa control system
Table of Contents

Advertisement

Setting up a 2-Speed Pump

Equipment circuits displayed on this screen will automatically switch a two speed filter pump to high speed
when these circuits are switched on. For example, the filter pump will switch from low speed to high speed
whenever the JETS or CLEANER circuit is switched on.
Go to the 2-Speed Pump screen to select your choice of heat options to force the pump to high speed:
Getting There
MENU SETUP EQUIPMENT 2-SPEED PMP
1. Press the button next to None. A small arrow is pointing to the select circuit name. "NONE" indicates that
the pump circuit has not been selected.
2. Use the Up and Down buttons at the bottom of the screen to
scroll through the previously assigned names to add another
circuit for switching filter pump to high speed. After you have
found the desired circuit. To add another circuit, repeat step 1,
or Press the Save button. A "FEATURE" circuit can be used
to switch the pump from low speed to high speed
(see page 79).
3. Press the Save button.
4. Press the Exit button to return to the main screen.
Note: With a dual equipment system i10+3D, the left column
controls the spa pump and the right column controls the pool
pump.
Master Spa/Pool (Heater Cool-Down) and Delays For Valves
Master Spa/Pool
This feature keeps the pump running for ten minutes after the heater is switched off to cool down the heaters header and
heat exchanger. Some heater models require this cool down period or damage will occur. This is sometime referred to
as the "Fireman Switch." for example, If you are in the spa, and you switch it off. The IntelliTouch will return the valves
to "Pool" mode position. If the pool is running a cycle, or the Fireman switch (Master Spa/Pool Delay) is enabled,
colder water from the pool would be pumped into the spa as the valves turn. Note: If the pool is not running a cycle,
and the fireman switch is not enabled, the pump stops and no pool water would be pumped into the spa as the valves
turn back to pool.
Delay For Valves
This feature creates a 30 second PUMP OFF (forced) period anytime the valves rotate. Either from pool
to spa, or spa to pool. When you switch the spa off, even if the pool is running a cycle or the fireman switch is enabled,
it stops the pump for 30 seconds while the valves turn, so colder water from the pool will not enter the spa. This feature
prevents cold water entering the spa when you start the spa, so less heating is needed. It also stops the pump when the
system is changing from pool to spa or back again in Freeze mode.
Continue on next page.
IntelliTouch Pool and Spa Control System User's Guide
75