Setting The Egg Timer Function - Intellitouch User Manual

Pool and spa control system
Table of Contents

Advertisement

Setting the Egg Timer Function

The "Egg Timer" feature lets you manually switch on equipment and switch off automatically after a specified
time. You can set this timer feature for other equipment such as lighting, the spa, or the spa jets. Equipment can
be programmed to be switched on for one minute to 24 hours. You can also use the "Don't Stop" feature to
override the 12 hour default switch off time, and run continuously until manually switched off.. If you have never
set the timer for a specific piece of equipment, the factory default time is set to 12 hours.
If you have a power outage, this feature will not switch the equipment back on, you need to use set the system
in "Service" mode at the outdoor control panel center to switch the equipment back on. For more information,
refer to "Using the Service Personnel Screen" on page 85.
Go to the PROGRAM/SELECT equipment screen. From this screen
you can select SPA, POOL or any of the AUX equipment circuits to
program.
The following example describes how to program the spa equipment
using the "Egg Timer" feature:
1. To program the spa filter pump and heater to switch on and off at a
specific time, press the button next to SPA to access the "Program/
Select" screen. If this is the first program, the program counter
displays (1/0). After this program is saved, (1/1) is displayed (see
step 6). Up to 99 total programs may be created for all circuits
combined.
2. Press the left side button next to HOURS until EGG TIMER is
displayed. (EGG TIMER is displayed one press after 11:00 PM).
3. Press the left side button next to HOURS (under EGG TIMER)
to set the count down run time in hours (from 00:00 to 23:00
hours). You can also select "DON'T STOP" to run the circuit
continuously until switched off manually. "DON'T STOP" is
displayed one press after 23:00.
4. Press the right side button next to MINS to set the run time
minutes.
Note: Press the button under CLEAR to reset the default settings.
5. For the "Egg Timer" feature ALWAYS is displayed, indicating the program will run and automatically shut-off
in the specified time.
6. Press Save to save the current program. The program counter displays (1/1) indicating that you have saved
one (1) program for the selected circuit.
7. Press the Back button to return to the SPA, POOL and AUX equipment selection screen to program other
equipment.
8. Press the Exit button to return to the main screen.
MENU/PROGRAM/SELECT
BACK
DISPLAY
SPA
SS_NO
EGGTIMER
MENU/PROGRAM/SPA
SMART
START
IntelliTouch Pool and Spa Control System User's Guide
17
EXIT
1/0
ALWAYS