Assigning a function and freeze protection to a circuit
To assign a function to an auxiliary circuit and to add circuit freeze protection:
1. Press the top right side button next to the displayed circuit names (i.e., CLEANER). The circuit displayed is
selected from the previous screen.
2. Use the left and right side button next to PREV and NEXT to select the function for this circuit. For example,
circuit function MASTER CLEANER selects the type of logic needed for a cleaner circuit. To assign a light
function, select IntelliBrite, SAM Light or SAL Light. For the complete list of circuit functions, see Special
Functions for Circuits, on page 41. Note: When using "pressure cleaners" assign the circuit to "Master
Cleaner."
3. Use the left and right side button next to ON WITH FREEZE to select YES for freeze protection. This will
activate the circuit if the air temperature drops below 36° F (2° C). Select NO for no freeze protection.
Note: Freeze protection is automatically enabled for SPA, POOL, HI-TEMP, and LOW-TEMP circuits.
MENU/SETUP/ADV/FUNC/CLEANER
4. Press the SAVE button when finished.
5. Press the BACK button to return to the Circuits screen and repeat steps 1 through 4 to assign functions to
other circuits.
6. Press EXIT button to return to the Main screen.
IntelliTouch Pool and Spa Control System User's Guide
(Continued)
Note: Spa operation and freeze protect time:
Using the "Spa Freeze Override" feature, the
freeze protect default time of 30 minutes can
be increase from 30 minutes to 240 minutes
maximum. For more information, see page 71.