logging local override

logging local override [class <class> priority <log-level>]
no logging local override [class <class> priority <log-level>]
Enables class-specific overrides to the local log level.
The no form of the command disables all class-specific overrides to the local log
level without deleting them from the configuration, but disables them so that the log-
ging level for all classes is determined solely by the global setting.
Syntax Description
override
class
log-level
Default
Override is disabled.
Modes/Context
Config
History
3.1.0000
Role
admin
Enables class-specific overrides to the local log level.
Sets or removes a per-class override on the logging
level. All classes which do not have an override set will
use the global logging level set with "logging local
<log level>". Classes that do have an override will do
as the override specifies. If "none" is specified for the
log level, MLNX-OS will not log anything from this
class.
Classes available:
iss-modules - protocol stack
mgmt-back - system management back-end
mgmt-core - system management core
mgmt-front - system management front-end
mlx-daemons - management daemons
sx-sdk - switch SDK
alert - alert notification, action must be taken immediately
crit - critical condition
debug - debug level messages
emerg - system is unusable (emergency)
err - error condition
info - informational condition
none - disables the logging locally and remotely
notice - normal, but significant condition
warning - warning condition