Stats Alarm <Alarm-Id> Event-Repeat - Mellanox Technologies Mellanox SX1018 Command Reference Manual

Ethernet managed blade switch
Hide thumbs Also See for Mellanox SX1018:
Table of Contents

Advertisement

stats alarm <alarm-id> event-repeat
stats alarm <alarm ID> event-repeat {single | while-not-cleared}
no stats alarm <alarm ID> event-repeat
Configures repetition of events from this alarm.
Syntax Description
alarm ID
single
while-not-cleared
Default
single
Modes/Context
Config
History
3.1.0000
Role
monitor/admin
Example
switch (config) # stats alarm cpu_util_indiv event-repeat single
switch (config) #
Related Commands
show stats alarm
Note
Alarms supported by the system, for example:
cpu_util_indiv - Average CPU utilization too high: per-
cent utilization
disk_io - Operating System Disk I/O per second too high:
kilobytes per second
fs_mnt - Free filesystem space too low: percent of disk
space free
intf_util - Network utilization too high: bytes per second
memory_pct_used - Too much memory in use: percent of
physical memory used
paging - Paging activity too high: page faults
temperature - Temperature is too high: degrees
Does not repeat events: only sends one event whenever
the alarm changes state.
Repeats error events until the alarm clears.
Mellanox Technologies
Rev 1.6.2
259

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sx1018hp

Table of Contents