stats alarm <alarm-id> rate-limit
stats alarm <alarm ID> rate-limit {count <count-type> <count> | reset | window
<window-type> <duration>}
Configures alarms rate limit.
Syntax Description
alarm ID
count-type
reset
window-type
Default
Short window: 5 alarms in 1 hour
Medium window: 20 alarms in 1 day
Long window: 50 alarms in 7 days
Modes/Context
Config
History
3.1.0000
Role
monitor/admin
Example
switch (config) # stats alarm paging rate-limit window long 2000
switch (config) #
Related Commands
show stats alarm
Note
Alarms supported by the system, for example:
cpu_util_indiv - Average CPU utilization too high: per-
cent utilization
disk_io - Operating System Disk I/O per second too high:
kilobytes per second
fs_mnt - Free filesystem space too low: percent of disk
space free
intf_util - Network utilization too high: bytes per second
memory_pct_used - Too much memory in use: percent of
physical memory used
paging - Paging activity too high: page faults
temperature - Temperature is too high: degrees
Long medium, or short count (number of alarms).
Set the count and window durations to default values
for this alarm.
Long medium, or short count, in seconds.