Lldp Tx-Hold-Multiplier - Mellanox Technologies Mellanox SX1018 Command Reference Manual

Ethernet managed blade switch
Hide thumbs Also See for Mellanox SX1018:
Table of Contents

Advertisement

lldp tx-hold-multiplier

lldp tx-hold-multiplier <seconds>
no lldp tx-hold-multiplier
The time-to-live value expressed as a multiple of the lldpMessageTxInterval object.
The no form of the command sets the parameter to default.
Syntax Description
seconds
Default
2
Modes/Context
Config
History
3.2.0300
Role
admin
Example
switch (config)# lldp tx-hold-multiplier 10
switch (config)#
Related Commands
show lldp timers
Note
The actual time-to-live value used in LLDP frames, can be expressed by the follow-
ing formula: TTL = min(65535, (lldpMessageTxInterval * lldpMessageTxHoldMul-
tiplier)) For example, if the value of lldpMessageTxInterval is '30', and the value of
lldpMessageTxHoldMultiplier is '4', then the value '120' is encoded in the TTL field
in the LLDP header.
1-8192
Mellanox Technologies
Rev 1.6.2