stats alarm <alarm-id> {rising | falling}
stats alarm <alarm ID> {rising | falling} {clear-threshold | error-threshold}
<threshold-value>
Configure alarms thresholds.
Syntax Description
alarm ID
falling
rising
error-threshold
clear-threshold
threshold-value
Default
Default is different per alarm-id
Modes/Context
Config
History
3.1.0000
Role
admin
Example
switch (config) # stats alarm cpu_util_indiv falling clear-threshold 10
switch (config) #
Related Commands
show stats alarm
Note
Not all alarms support all four thresholds.
Alarms supported by the system, for example:
cpu_util_indiv - Average CPU utilization too high: per-
cent utilization
disk_io - Operating System Disk I/O per second too high:
kilobytes per second
fs_mnt - Free filesystem space too low: percent of disk
space free
intf_util - Network utilization too high: bytes per second
memory_pct_used - Too much memory in use: percent of
physical memory used
paging - Paging activity too high: page faults
temperature - Temperature is too high: degrees
Configures alarm for when the statistic falls too low.
Configures alarm for when the statistic rises too high.
Sets threshold to trigger falling or rising alarm.
Sets threshold to clear falling or rising alarm.
The desired threshold value, different per alarm.