External
I/O Expansion Unit
TABLE 4-2
Item
Description
Display list
Displays a list of External I/O Expansion
Units and downlink cards. The following is
displayed:
• Set External I/O Expansion Unit numbers
and downlink card paths
• Exernal I/O Expansion Units, I/O boards,
link cards (Note 1), downlink cards, PSU
types, firmware versions, serial numbers,
part numbers, and states
Display
Displays the status of the environment of the
environment
specified External I/O Expansion Unit or
information
downlink card as sensor measurement values.
The following is displayed:
• Current (A)
• Voltage (V)
• FAN speed (RPM)
• Temperature (C)
• LED state
Display/set
Displays and sets the locator LED state for
locator LED
individual components in the specified
(Note 2)
External I/O Expansion Unit.
Each locator LED is in one of the following
states:
• Blinking
• Lit
• Off
Any of the following locator LED states can be
set:
• Enabled (on)
• Disabled (off)
Power on/off Turns on or off power to the specified I/O
board or PSU.
Note: To forcibly disconnect an IO board
belonging to a domain, use the -f option.
Note – (1) Also called uplink cards. They are mounted on I/O boards.
4-26
SPARC Enterprise Mx000 Servers XSCF User's Guide • April 2008
Administration
Shell Command
ioxadm
ioxadm
ioxadm
ioxadm
Remarks
External I/O Expansion
Unit numbers are set in two
ways: specifying last four
digits of serial numbers
such as iox@nnnn, and
specifying instance
numbers such as ioxn.
Also, the preciseness is
displayed together with the
sensor measurement
values.
Only one locator LED can
be enabled or disabled at a
time in an External I/O
Expansion Unit.
Even after the power
switch is set to off, LEDs
and FANs continue
operating as long as they
are supplied with power.