B.2 Power Log - Fujitsu SPARC Enterprise M4000 User Manual

Fujitsu server user's guide
Hide thumbs Also See for SPARC Enterprise M4000:
Table of Contents

Advertisement

3. After confirming the problem, repair the fault according to the recommended
processing.
For details of the fmdump (8) command, see the XSCF Reference Manual or the main
page.
B.2
Power Log
When a power operation or resetting is performed in the server or domain, the XSCF
firmware collects a power log. This section explains how to reference the power log.
See
TABLE 8-3
Using the showlogs (8) Command to Reference Power Logs
Specify the power option on the XSCF Shell and perform the showlogs (8)
command to reference power logs.
<Example 1>
Power logs are displayed as a list.
XSCF> showlogs power
Date
Mar 30 17:25:31 JST 2005
Mar 30 17:35:31 JST 2005
Mar 30 17:45:31 JST 2005
Mar 30 17:50:31 JST 2005
<Example 2>
Power logs are listed in order of the most-to-least recent by
specifying a start time and end time.
XSCF> showlogs power -t Mar3017:302005 -T Mar3017:492005 -r
Date
Mar 30 17:45:31 JST 2005
Mar 30 17:35:31 JST 2005
(The examples are subject to change without previous notice for functional
improvement.)
In the examples above, the following items are displayed:
Time at which each power log was collected (Date). This is indicated in local time.
Type of power event that occurred (Event). The following lists each event and its
meaning:
for the size and generation number of a power log.
Event
System Power Off
System Power On
Domain Power Off
Domain Power On
Event
Domain Power Off
System Power On
Cause
DID
Power Failure
--
AC Restored
--
Operator
00
Operator
00
Cause
DID
Operator
00
AC Restored
--
Appendix B
XSCF Log Information
Switch
Service
Locked
Locked
Service
Switch
Locked
Locked
B-5

Advertisement