Table 8-2 Firmware Update Tasks - Fujitsu SPARC Enterprise M4000 User Manual

Fujitsu server user's guide
Hide thumbs Also See for SPARC Enterprise M4000:
Table of Contents

Advertisement

Firmware Update Tasks
TABLE 8-2
Firmware Update Task Item
Updating XCP From the
Network
Updating XCP From External
Media
(When the XCP file is copied
onto external media such as a
CD-ROM.)
Confirm That the OpenBoot
PROM Firmware is Updated
When a CMU Has Been Added
or Replaced
Confirming That the XSCF
Firmware is Updated When an
XSCF Unit Has Been Replaced
(There Are Redundant XSCF
Units)
Confirming That the XSCF
Firmware is Updated When the
XSCF Unit Has Been Replaced
(in a System With a Single XSCF
Unit or Both Replacement in a
System With Redundant XSCF
Units)
8-10
SPARC Enterprise Mx000 Servers XSCF User's Guide • April 2008
Outline
Obtain the XCP files from the
appropriate web site, and use XSCF to
import XCP. Use XSCF Web or the XSCF
Shell for the firmware update.
Reboot the system for application to all
domains.
Note:
If the system has redundant XSCF Units,
the XSCF Units are switched while the
update is in progress.
Imports XCP from the CD-ROM disk by
using XSCF. Use the XSCF Web or the
XSCF Shell for the firmware update.
The rest of the task is the same as
updating XCP from the network.
The firmware update is automatically
performed.
Confirm the version of the OpenBoot
PROM firmware in the update target
domain.
The firmware update is automatically
performed by using the maintenance
guidance for FE. (Note)
Confirm the version of the updated XCP.
Note: When a component is replaced in
the state of main line switch off (input
power cable off in midrange systems)
(the cold replacement), the firmware is
not updated automatically. The operator
must match the number of the versions.
The firmware is not updated
automatically. The operator must match
the number of the firmware versions.
Task time
• In the system with a XSCF
Unit; About 45 minutes
• In the system with redundant
XSCF Units; About 120 minutes
(Excludes the time for component
replacement work)
• In the system with a XSCF
Unit; About 45 minutes
• In the system with redundant
XSCF Units; About 120 minutes
(Excludes the time for component
replacement work)
About 5 minutes
(Excludes the time for component
replacement work)
About 5 minutes
(Excludes the time for component
replacement work)
• In the system with a XSCF
Unit; about 20 minutes
• In the system with redundant
XSCF Units; about 40 minutes
(Excludes the time for component
replacement work)