4. Use the showstatus (8) command to display information on degraded
components in the system.
XSCF> showstatus
*
BP_A Status:Degraded;
*
DDC_A#0 Status:Faulted;
*
PSU#0 Status:Faulted;
(This screenshot is provided as an example.)
5. Use the showenvironment (8) command to display the ambient temperature,
humidity, and voltage of the system.
XSCF> showenvironment
Temperature:30.70C
Humidity:90.00%
XSCF> showenvironment temp
Temperature:30.70C
CMU#0:43.00C
CPUM#0-CHIP#0:65.00C
CPUM#1-CHIP#0:61.20C
CPUM#2-CHIP#0:64.80C
CPUM#3-CHIP#0:63.60C
CMU#1:45.50C
:
XSCF>
showenvironment volt
MBU_B
1.0V Power Supply Group:1.000V
1.8V Power Supply Group:1.910V
CPUM#0-CHIP#0
1.0V Power Supply Group:1.050V
:
(This screenshot is provided as an example.)
Note – The humidity information is only displayed in high-end systems.