Email Subject
NFS File Logging
NFS File Logging
Directory to Log to
Max Number of
Files
Max Size of Files
PC Card Logging
PC Card Logging
Log To
Max Number of
Files
Max Size of Files
3. To save, click Apply.
SecureLinx SLC User Guide
A subject text appropriate for your site. May have up
to 128 characters.
The email subject line is pre-defined for each port with its
port number. You can use the email subject to inform the
desired recipients of the problem on a certain server or
location (e.g., server location or other classification of your
equipment). This is helpful if the email message goes to
the system administrator's or service technician's mobile or
wireless device (e.g., text messaging by means of email).
Note:
The character sequence %d anywhere in the email
subject is replaced with the device port number
automatically.
Select the checkbox to log all data sent to the device port
to one or more files on an external NFS server. Disabled
by default.
The path of the directory where the log files will be stored.
Note:
This directory must be a directory exported from an
NFS server mounted on the SLC. Specify the local
directory path for the NFS mount.
The maximum number of files to create to contain log data
to the port. These files keep a history of the data received
from the port. Once this limit is exceeded, the oldest file is
overwritten. The default is 10.
The maximum allowable file size in bytes. The default is
2048 bytes. Once the maximum size of a file is reached,
the SLC begins generating a new file.
Select to enable PC Card logging. A PC Card Compact
Flash must be loaded into one of the PC Card slots on the
front of the SLC and properly mounted (see
Disabled by default.
If port logging is to a PC Card, select the slot (Upper or
Lower) in which the PC Card has been inserted. Upper is
the default.
The maximum number of files to create to contain log data
to the port. These files keep a history of the data received
from the port. Once this limit is exceeded, the oldest file is
overwritten. The default is 10.
The maximum allowable file size in bytes. The default is
2048 bytes. Once the maximum size of a file is reached,
the SLC begins generating a new file. The default is 2048
bytes.
8: Device Ports
11: PC Card
).