3-6 Compaq ProLiant ML750 Servers Setup and Installation Guide

Power Supply LEDs

Each power supply has status and AC power LEDs. See Figure 3-1 and
Table 3-1 for a detailed description of both LEDs.
Figure 3-1. Power supply LEDs
LED
Condition
Green
Status

Green/Amber alternating
Green flashing
Amber
Amber flashing
Off
Green
AC Power

Off
Table 3-1
Power Supply LEDs
Meaning
Normal operation
Power supply failed to restart after a prolonged
fault
Power supply will restart within 20 seconds
Fault detected in this power supply
Failed self-test
System is in Standby or interlocks are disabled
AC power is connected to this power supply
AC power is not connected to this
power supply