D-8 Compaq ProLiant ML750 Servers Setup and Installation Guide

Power Supply LED Indicators

Each power supply has status and AC power indicators. See Figure D-6 and
Table D-3 for a detailed description of both indicators.
Figure D-6. Power supply indicators
Item
Condition
Green
S tatus


Green/Amber
alternating
Green flashing
Amber
Amber flashing
Off
Green
A C Power


Off
Table D-3
Power Supply Indicators
Meaning
Normal operation
Power supply failed to restart after a
prolonged fault
Power supply will restart within 20 seconds
Fault detected in this power supply
Failed self-test
System in standby mode or interlocks
disabled
AC power is connected to this power supply
No AC power is connected to this supply