Proline Promass A 100 PROFINET
Parameter
Zero point adjustment control
Progress
Parameter
Assign process variable
Unit totalizer
Endress+Hauser
Navigation
"Setup" menu → Advanced setup → Sensor adjustment → Zero point adjustment
‣
Zero point adjustment
Zero point adjustment control
Progress
Parameter overview with brief description
Description
Start zero point adjustment.
Shows the progress of the process.
10.7.4
Configuring the totalizer
In the "Totalizer 1 to n" submenu, you can configure the specific totalizer.
Navigation
"Setup" menu → Advanced setup → Totalizer 1 to n
‣
Totalizer 1 to n
Assign process variable
Unit totalizer
Totalizer operation mode
Failure mode
Parameter overview with brief description
Prerequisite
–
One of the following options is
selected in the Assign process
variable parameter:
• Mass flow
• Volume flow
• Corrected volume flow
*
• Target mass flow
*
• Carrier mass flow
Selection / User interface
• Cancel
• Busy
• Zero point adjust failure
• Start
0 to 100 %
Description
Select process variable for
totalizer.
Select the unit for the process
variable of the totalizer.
Commissioning
→ 77
→ 77
Factory setting
–
–
→ 77
→ 77
→ 78
→ 78
Selection
Factory setting
• Volume flow
–
• Mass flow
• Corrected volume
flow
Unit choose list
Country-specific:
• kg
• lb
77