Diagnostics and troubleshooting
120
Info number
I1256
Display: access status changed
I1335
Firmware changed
I1361
Web server login failed
I1397
Fieldbus: access status changed
I1398
CDI: access status changed
I1444
Device verification passed
I1445
Device verification failed
I1446
Device verification active
I1447
Record application reference data
I1448
Application reference data recorded
I1449
Recording application ref. data failed
I1450
Monitoring off
I1451
Monitoring on
I1457
Measured error verification failed
I1459
I/O module verification failed
I1460
Sensor integrity verification failed
I1461
Sensor verification failed
I1462
Sensor electronic module verific. failed
I1512
Download started
I1513
Download finished
I1514
Upload started
I1515
Upload finished
I1627
Web server login successful
I1631
Web server access changed
I1649
Hardware write protection activated
I1650
Hardware write protection deactivated
12.10 Resetting the measuring device
The entire device configuration or some of the configuration can be reset to a defined state
with the Device reset parameter (→ 78).
12.10.1 Function range of "Device reset" parameter
Options
Description
Cancel
No action is executed and the user exits the parameter.
To delivery settings
Every parameter for which a customer-specific default setting was ordered is reset
to the customer-specific value. All other parameters are reset to the factory setting.
Restart device
The restart resets every parameter with data stored in volatile memory (RAM) to
the factory setting (e.g. measured value data). The device configuration remains
unchanged.
Info name
This option is not visible if no customer-specific settings have been ordered.
Proline Promass A 100 PROFINET