Global diagnostic variables
Variable name
ACK_REQ_FSOE_MSTR_GLOBAL
Acknowledge request At least one FSoE connection waits for an operator acknowledge request, e.g. after a change
from fail-safe to process data communication.
Global equivalent to FSOE_MSTR_ADDR_xxxx_ACK_REQ.
At least one communication instance behaves as described in FSOE_MSTR_ADDR_xxxx_ACK_REQ.
ACK_REI_FSOE_MSTR_GLOBAL
Acknowledge reintegration All previous ACK_REQs for this FSoE connection are acknowledged.
Global equivalent to FSOE_MSTR_ADDR_xxxx_ACK_REI.
Set all communication instances as described in FSOE_MSTR_ADDR_xxxx_ACK_REI.
If a specific ACK_REI is set, the global ACK_REI must not be enabled.
PASS_OUT_FSOE_MSTR_GLOBAL
Passivation enabled on input side: At least one FSoE connection sends fail-safe.
Global equivalent to FSOE_MSTR_ADDR_xxxx_PASS_OUT.
At least one communication instance behaves as described in FSOE_MSTR_ADDR_xxxx_PASS_OUT.
CE_CRC_FSOE_MSTR_GLOBAL
CRC error on input side: At least one FSoE connection has recognized a CRC error in the incoming FSoE PDU.
Global equivalent to FSOE_MSTR_ADDR_xxxx_CE_CRC.
At least one communication instance behaves as described in FSOE_MSTR_ADDR_xxxx_CE_CRC.
WD_TIMEOUT_FSOE_MSTR_GLOBAL
Watchdog timeout on input side: At least one FSoE connection has a watchdog timeout.
Global equivalent to FSOE_MSTR_ADDR_xxxx_WD_TIMEOUT.
At least one communication instance behaves as described in FSOE_MSTR_ADDR_xxxx_WD_TIMEOUT.
COMM_FSOE_MATR_GLOBAL
Global equivalent to FSOE_MSTR_ADDR_xxxx_COMM.
At least one communication instance behaves as described in FSOE_MSTR_ADDR_xxxx_COMM.
HB700 | CPU | PMC921xEx | en | 24-04
System variables and status information > FSoE diagnostic variables
Data direction
DI
DQ
DI
DI
DI
DI
Deployment CPU iC921xM-FSoE