System Variables - YASKAWA iC9200 Series Operating Manual

Hide thumbs Also See for iC9200 Series:
Table of Contents

Advertisement

Deployment CPU iC921xM-EC
System variables and status information > System variables
4.10.2

System variables

System time
System variable
RTC
HOURS
MINUTES
SECONDS
DAY
MONTH
YEAR
100
6.
Click the
button.
�� The 'Init Value Configuration' of the selected system variable organized as a data
structure is opened below the Data list editor.
In 'Init Value Configuration' column Element name lists all system variables
which are contained in the system variable organized as a data structure.
The system variable RTC is a system variable organized as a data structure.
You can use the RTC system variable to retrieve information about the system time of
the device-internal real-time clock.
Type - description
RTC_TYPE - data structure
USINT - system time (hours)
USINT - system time (minutes)
USINT - system time (seconds)
USINT - system time (day)
USINT - system time (month)
UINT - system time (year)
HB700 | CPU | PMC921xEx | en | 24-04
iC9200 Series