General
Approvals, directives, standards
EMC
Emitted interference
Noise immunity
zone B
1) Due to the high-energetic single pulses with Surge an appropriate external protective circuit with lightning protection elements like conductors for lightning and over-voltage is
necessary.
Example of lightning protection conductors
Application
Feed
Digital inputs,
test pulse outputs
Digital outputs
EtherCAT interface
Norms and standards
DIN EN 61508 part 1-7
DIN EN ISO 13849-1
DIN EN 61784-3
DIN EN 60204-1
DIN EN 61131-2
DIN EN 61000-4-11
Row SN 29500
DIN EN 61496-1
20
Standard
EN 61000-6-4
EN 61000-6-2
EN 61000-4-2
EN 61000-4-3
EN 61000-4-6
EN 61000-4-4
EN 61000-4-5
Vendor
Dehn
Dehn
Dehn
Dehn
Functional safety of electrical/electronic/programmable electronic safety-
related systems
Safety of machinery: Safety-related parts of control systems
Functional safety field buses - General rules and profile definitions
Electrical equipment of machines
Programmable logic controllers,
part 2: Equipment requirements and tests
Mains voltage variation
Failure rate, component, expected value, reliability
Electro sensitive protective equipment
Comment
Class A (Industrial area)
Industrial area
ESD
8kV at air discharge (degree of severity 3),
4kV at contact discharge (degree of severity 2),
HF field immunity (casing)
80MHz ... 1000MHz, 10V/m
1.4GHz ... 6.0GHz, 3V/m
HF conducted
150kHz ... 80MHz, 10V
Burst, degree of severity 3
Surge, degree of severity 3
Article
BLITZDUCTOR VT
BVT AVD 24
DEHNconnect RK
DCO RK ME 24
DEHNconnect RK
DCO RK D 5 24
DEHNpatch
DPA M CLE RJ45B 48
HB700 | CPU | PMC921xEx | en | 24-04
iC9200 Series
1
Description
External Lightning protec-
tion
(DC24V/10A)
External Lightning protec-
tion
(DC24V/0.5A)
External Lightning protec-
tion
(DC24V/10A)
External Lightning protec-
tion
(RJ45/48V)