Commissioning > Online access to the CPU
5.5.1.1
Notes on initial commissioning
5.5.2

Online access to the CPU

IP address parameters for
communication
118
WARNING
Safety-related steps
The following steps include safety-related activities in the iCube Engineer
software and the safety validation of the FSoE system.
Please also note the checklists listed in the appendix for the following
steps.
Please also refer to the online help of the iCube Engineer.
WARNING
Carry out verification in accordance with safety standards
For all steps in creating the security program for your application, carry
out verification in accordance with the security standards applicable to
your application.
NOTICE
Unauthorized access to the SD card possible
Access to the SD card is possible so that data can be read and manipulated.
Please note
access protection for the SD card.
On delivery the following IP address parameters for the communication are preset in the
project template of the CPU:
Ethernet-Port (X3/X4): 192.168.1.1
Subnet mask: 255.255.255.0
Gateway: -
If your CPU has different IP address parameters, you can adapt them for iCube Engineer
via the following procedure:
1.
Open your project.
2.
In the 'Plant' area, double-click the CPU node
�� The CPU editor group opens.
3.
Select the 'Settings' editor.
4.
Select the 'Ethernet' view.
��
5.
At 'LAN (X3/X4)' the IP address parameters for the connection via the Ethernet-
Port (X3/X4) can be set.
�� When establishing an Ethernet connection to the CPU, the IP address parame-
ters specified here are used by iCube Engineer for the corresponding interface.
⮫ 'Notes on security'...page