Liquiphant FTL51B Density
Endress+Hauser
Cable entries
• M20 coupling, plastic, IP66/68 NEMA Type 4X/6P
• M20 coupling, nickel-plated brass, IP66/68 NEMA Type 4X/6P
• M20 coupling, 316L, IP66/68 NEMA Type 4X/6P
• M20 coupling, 316L, hygienic, IP66/68/69 NEMA Type 4X/6P
• M20 thread, IP66/68 NEMA Type 4X/6P
• G ½ thread, NPT ½, NPT ¾ IP66/68 NEMA Type 4X/6P
Degree of protection for M12 plug
• When housing is closed and connecting cable is plugged in: IP66/67 NEMA Type 4X
• When housing is open or connecting cable is not plugged in: IP20, NEMA Type 1
NOTICE
M12 plug: Loss of IP protection class due to incorrect installation!
The degree of protection only applies if the connecting cable used is plugged in and
screwed tight.
The degree of protection only applies if the connecting cable used is specified according
to IP67 NEMA Type 4X.
If the "M12 plug" option is selected as the electrical connection, IP66/67 NEMA Type
4X applies for all housing types.
15.3.6

Pollution degree

Pollution degree 2
15.4

Process

15.4.1

Process temperature range

0 to 80 °C (32 to 176 °F)
15.4.2

Thermal shock

≤ 120 K/s
15.4.3

Process pressure range

–1 to +25 bar (–14.5 to +362.5 psi)
WARNING
L
The maximum pressure for the device depends on the lowest-rated element, with
regard to pressure, of the selected component. This means that it is necessary to pay
attention to the process connection as well as the sensor.
Pressure specifications, see the associated Technical Information.
Only operate the device within the specified limits!
The Pressure Equipment Directive (2014/68/EU) uses the abbreviation "PS". The
abbreviation "PS" corresponds to the MWP (maximum working pressure) of the device.
Canadian CRN approval: more details about the maximum pressure values are
available in the download area of the product page under: www.endress.com→
Downloads.
15.4.4

Pressure tightness

Up to vacuum