• In through mode, only outputs 1 and multiples of 4 + 1
(1, 5, 9, and so on) can be configured.
• Ancillary data is deleted from the signals on inputs 1
and multiples of 4 + 1 (1, 5, 9, and so on).
• In a 1M/E box switcher configuration, ancillary data is
deleted in the following cases.
System signal
Output conditions
format
2160P
• When signals on port numbers 1, 5,
9, and 13 are output on port numbers
17, 21, 25, and 29
• When signals on port numbers 17,
21, 25, and 29 are output on port
numbers 1, 5, 9, and 13
1080P, 1080i
• When signals on port numbers 1, 5,
9, 13, 17, 21, 25, 29, and 32 are
output on port numbers 33, 37, 41,
45, 49, 53, 57, and 61
• When signals on port numbers 33,
37, 41, 45, 49, 53, 57, and 61 are
output on port numbers 1, 5, 9, 13,
17, 21, 25, 29, and 32
1
Open the Home > Setup > System > Output > Output
Assign menu (19101.41).
2
Select the target output to set.
To select and set multiple outputs, place a check mark
beside the target outputs to set.
To select and set all outputs, place a check mark in the
Select All checkbox.
3
Enable/disable through mode using the [Through
Mode] switch.
On: Enable through mode.
Off: Disable through mode.

Setting the Video Clip Function

1
Open the Home > Setup > System > Output > Video
Adjust menu (19101.42).
2
Select a tab to switch the target to set.
[Output] tab: Output video clip settings
[Dedicated Out] tab: Dedicated output video clip
settings
3
Select the target output to set and set the following
parameters.
No.
Parameter
1
White Clip
Adjustment
Luminance signal white clip
value
No.
Parameter
2
Dark Clip
3
Chroma Clip
To return the settings to the defaults
Press the [Reset] button.

Setting the Safe Title Area

1
Open the Home > Setup > System > Output > Safe
Title menu (19101.43).
2
Select a tab to switch the target to set.
[Output] tab: Output safe title settings
[Dedicated Out] tab: Dedicated output safe title
settings
3
Select the target output to set.
4
Set the safe title area display method.
To display box 1
Set the [Box1] button to the on state.
Set the following parameter.
No.
Parameter
1
Size
In the [Box1 Adjust] group, select an aspect ratio
(16:9, 14:9, 4:3).
To display box 2
Set the [Box2] button to the on state.
Set the following parameters.
No.
Parameter
1
Size
2
Luminance
In the [Box2 Adjust] group, select an aspect ratio
(16:9, 14:9, 4:3).
To display a cross
Set the [Cross] button to the on state.
To display a grid
Set the [Grid] button to the on state.
In the [Grid Adjust] group, select an aspect ratio
(16:9, 4:3).
In the [Grid Size] group, select a size (80.00%,
85.00%, 90.00%, 100.00%).
To return the settings to the defaults
Press the [Reset] button.
375
Adjustment
Luminance signal dark clip
value
Chrominance signal clip value
Adjustment
Size
Adjustment