Three-Dimensional Transform Operations (Menu) - Sony MLS-X1 User Manual

Live production processor system
Hide thumbs Also See for MLS-X1:
Table of Contents

Advertisement

Note
You can also enter a difference value from the currently
set value using the [TRIM] button.
For details, see "Entering a difference from a current
value" (page 79).
To change parameters to the closest detent
position
Press the [CTR] button once.
For details about detents, see "Detents" (page 196).
To return the parameters to the default values
Press the [CTR] button twice. Or press and hold the
[SHIFT] button and press the [CTR] button.
For details about default values, see "Three-dimensional
parameter setting values" (page 195).
To return parameters to the initial settings
The parameters return to the initial status saved data
setting values.
The operation must be performed separately for global
space and local space.
For details about initial status, see "Setting Startup"
(page 359).
To return three-dimensional parameters to the initial
settings:
Press the [CLR WORK BUFR] button once.
To return all DME parameters to the initial settings:
Press the [CLR WORK BUFR] button twice. Or press
and hold the [SHIFT] button and press the [CLR
WORK BUFR] button.
Three-Dimensional Transform
Operations (Menu)
This section describes the menu for DME channel 1 as an
example.
Adjusting three-dimensional parameters
1
Open the Home > DME > Channel1 > 3D Transform
> Adjust menu (15101.11).
2
In the [Local/Global] group, select local space or
global space.
Local: Local space
Global: Global space
Both local space and global space can be selected.
3
In the [Source/Target] group, select source space or
target space.
Source: Source space
Target: Target space
Either source space or target space can be selected.
4
Set the target three-dimensional transform operation
X-axis, Y-axis, and Z-axis parameters.
When local space is selected
Press the [X] button, [Y] button, or [Z] button for
[Local], and enter a setting value in the numeric
keypad window.
When global space is selected
Press the [X] button, [Y] button, or [Z] button for
[Global], and enter a setting value in the numeric
keypad window.
To adjust parameters using the analog controls
section
Press the button for the target three-dimensional
transform operation to set, and set the [X] parameter,
[Y] parameter, and [Z] parameter in the analog
controls section.
When both local space and global space are selected,
the parameter buttons for local space are displayed on
the 1st page and the parameter buttons for global
space are displayed on the 2nd page. Set the
parameters for local space on the 1st page and the
parameters for global space on the 2nd page.
Configurable three-dimensional parameters
The parameters that can be set vary depending on the
three-dimensional transform operation buttons.
Location Size: Scale image (shrink/magnify)
Only the Z-axis in source space can be configured.
All axes in target space can be configured.
Location XYZ: Move image
All axes can be configured.
Rotation: Rotate image (rotation mode)
All axes can be configured.
Spin: Rotate image (spin mode)
All axes can be configured.
Aspect: Change image aspect ratio
Only the source space of the local space can be
configured.
Skew: Change image skew
Only the X-axis and Y-axis in the source space of the
local space can be configured.
Perspective: Change viewpoint position
Only target space can be configured.
Axis Location: Move rotation axis
Only source space can be configured.
To change parameters to the closest detent
position
Press the [Detents] button.
202

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents