To replace KeyFob: select the required Wireless key,
then enter the ESN of the new Wireless Key in the Se -
rial Number field.
To enrol a KeyFob: select an empty key placement
(ESN = 0) then enter the Wireless Key ESN in the Serial
Number field.
To unenrol a KeyFob: select the required Wireless Key
then enter 000000 in the Serial Number field.
+
If you press the SHIFT button and click on A or B
Arming type the arming mode will change on all the
partitions.
+
If you click on Partition number the arming mode
will change on all the KeyFobs.

Clock

Proper functioning of the Scheduler/Timers depends on
the Clock setting (Clock page), therefore, the Control
panel clock must be set with extreme precision.
Actual Date Set the current date.
Actual Time Set the current time.
Date format Select the Keypad date format:
Ø dd/mm/yyyy = day/month/year
Ø mm/dd/yyyy = month/day/year
Ø yyyy/mm/dd = year/ month/day
Figure 52 Wiring diagram for the serial link between the Control panel and PC
84
1
6
2
7
3
8
4
9
5
a)
DB9 female
connector
5
9
4
8
3
7
2
6
1
b)
DB9 female
connector

On-site downloading

Once the operating parameters have been set up, they must
be downloaded to the Control Panel concerned, as follows.
+
Access to Programming requires the Installer
Code PIN.
1. Connect the Control Panel serial port (24) to one of
the PC serial ports, as follows:
– using a CVSER/9F9F link (accessory item), or a
cable similar to the one in Figure 52a, connect the
Control Panel to the PC;
– if the PC serial port has 25 pins, use an
ADSER/9M25F adapter (accessory item), or a ca-
ble similar to the one in Figure 52b.
2. Select the PC serial port used for connection with
the Control panel, as follows:
– select Serial Ports from the Settings menu;
– select the serial port (Control Panel section);
– select the number of attempts (Attempts box)
and Baud Rate;
– click Download (Baud Rate section) or OK.
7-wire cable
shield
7-wire cable
shield
1
6
2
7
3
8
4
9
5
DB9 female
connector
13
25
12
24
11
23
10
22
9
21
8
20
7
19
6
18
5
17
4
16
3
15
2
14
1
DB25 female
connector