How To Install The Floor Casters Assembly - Sun Microsystems Enterprise 250 Owner's Manual

Hide thumbs Also See for Enterprise 250:
Table of Contents

Advertisement

How to Install the Floor Casters
Assembly
Before You Begin
Complete these tasks:
"How to Power Off the System" on page 26
"How to Remove the Chassis Foot Glides" on page 150
What to Do
1. Carefully turn the system chassis upside down.
Enlist the help of another person to accomplish this safely.
Do not lift the chassis using the plastic panels at the front or the side of the chassis.
Place the system onto a solid surface that spaces the unit about 2 inches (5 cm) off
the floor; for example, use a pair of wooden boards. Do not allow any of the weight
to rest on the plastic panels at the front of the chassis.
Note – The right side of the casters assembly mounts to the two foot glide mounting
brackets on the underside of the chassis. If you removed these brackets previously,
you must reinstall them now. See "How to Install the Chassis Foot Glides" on
page 152.
2. Align the holes in the floor casters assembly with the corresponding mounting
holes on the underside of the chassis.
Position the casters assembly with the four casters facing up. Align the two large
holes in the assembly with the large holes in the chassis bottom.
148
Sun Enterprise 250 Server Owner's Guide • June 1998