Power Supply X NOT
okay.
Power supply X inserted
Power supply X removed
WARNING: Fan failure
has been detected
If the environmental monitoring system detects a temperature problem, it also lights
the temperature LED on the status and control panel. If it detects a power supply
problem, it lights the power supply fault LED on the panel. The LEDs located on the
power supplies themselves will help to further identify the problem. For information
about system LEDs, see:
"About the Status and Control Panel" on page 8
"Front Panel LEDs" on page 242
"Power Supply LEDs" on page 245
Note – Enterprise 250 power supplies will shut down automatically in response to
certain over-temperature and power fault conditions (see "Environmental
Monitoring and Control" on page 42). To recover from an automatic shutdown, you
must disconnect the AC power cord, wait approximately 10 seconds, and then
reconnect the power cord.
262
Sun Enterprise 250 Server Owner's Guide • June 1998
Type
Description
Warning
Indicates that there is something wrong
with the DC output of the supply. The
system may shut down abruptly if the
redundant power supply fails. The value X
identifies the power supply, PS0 is the lower
power supply; PS1 is the upper power
supply.
Advisory
A hot-swap feature to tell you that the
power supply identified by X was installed
without service disruption.
Advisory
A hot-swap feature to tell you that the
power supply identified by X was removed
without service disruption.
Warning
Indicates a fan failure in the fan tray
assembly.