OBDiag Commands
The following table provides information about the OBDiag interactive commands
that are available at the OBDiag command prompt:
Command
exit
help
printenvs
setenv variable value
test-all
test #,#, ...
except #,#, ...
what #,#, ...
OBDiag Configuration Variables
The following table provides information about OpenBoot PROM configuration
variables that affect the operation of OBDiag. Use the printenvs command to show
current values and the setenv command to set or change a value. Both commands
are described in "OBDiag Commands" on page 225.
Variable
Setting
diag-level
off
min
med
max
Description
Exits the OBDiag tool and returns to the ok prompt.
Displays a brief description of each command and OpenBoot PROM variable used
to run OBDiag.
Displays the value of all of the OBDiag variables. (See "OBDiag Configuration
Variables" on page 225 for information about settings.)
Sets the value for an OpenBoot PROM configuration variable. (See "OBDiag
Configuration Variables" on page 225 for information about settings.)
Runs all of the tests displayed in the menu.
Runs only the test(s) identified by menu entry number (#) in the command line.
Run all test(s) except those identified by menu entry number (#) in the command
line.
Displays selected properties of the device(s) identified by menu entry number (#)
in the command line. The exact information provided varies according to
device type.
Description
No tests are run at power up.
Performs minimal testing of core functionality.
Performs functional tests for all system
functions.
Runs exhaustive tests for all functions except
external loopbacks. External loopback tests are
run only if diag-targets is set to loopback,
loopback3, device&loopback, or
device&loopback,3.
Chapter 11
Diagnostics and Troubleshooting
Default
min