3. Reconnect all cables that you previously detached from the power distribution
board.
Start at the top of the board and work your way down.
a. Connect the keyswitch/LED cable at connector J0401.
b. Connect the system interlock cable at connector J0501.
c. Connect the two power sense cables at connectors J0201 and J0202.
d. Connect the DC power cables at connectors J0204, J0205, and J0206.
e. Connect the UltraSCSI power cable at connector J0207.
What Next
To reassemble the system, complete these tasks:
"How to Install the Fan Tray Assembly" on page 126
"How to Install the Side Access Panel" on page 33
"How to Install a Power Supply" on page 130
When you are ready to restart the system, be sure to run POST and OpenBoot
Diagnostic tests to verify that the system functions correctly with the new parts you
have just installed. For additional information, see Chapter 11 "Diagnostics and
Troubleshooting" beginning on page 215.