4. Simultaneously, pull and hold the slide rail release buttons on each mounting
bracket while you push the server into the rack (see
5. Continue pushing until the slide rail locks on the front of the mounting brackets
engage the slide rail assemblies.
Caution – Verify that the server is securely mounted in the rack and that the slide
rails locks are engaged with the mounting brackets before continuing.

Installing the Cable Management Arm

The section contains procedures to install the optional cable management assembly
(CMA), to route and attach the cables, and to verify the operation of the CMA.

To Install the Cable Management Assembly

1. Unpack the CMA parts.
2. Take the CMA to the rear of the equipment rack and ensure that you have
adequate room to work around the rear of the server.
Note – References to "left" or "right" in this procedure assume that you are facing
the rear of the equipment rack.
3. Locate the CMA rail extension and insert it into the left slide rail until the
extension locks into place with an audible click (
10
Sun Fire V210 and V240 Servers Installation Guide • November 2005
).
FIGURE 2-3
).
FIGURE 2-4