Online commands

11.1.3 'Online' commands for the parameter set operations

Copying parameter set
Command
Description
Parameter
Acknowledge-
ment
132
This command can only be used to copy parameter sets in their
entirety. This can be used to replicate the three parameter sets default,
permanent and operating parameters on the basis of one another. In
addition, this command can also be used to restore the factory settings.
'PC<Source type><Target type>'
<Source type>Parameter data set which is to be copied, unit [dimen-
sionless]
'0'
Parameter data set in permanent memory
'2'
Default or factory parameter set
'3'
Operating parameter data set in volatile memory
<Target type>Parameter set to which the data is to be copied, unit
[dimensionless]
'0'
Parameter data set in permanent memory
'3'
Operating parameter data set in volatile memory
Permissible combinations here include:
'03'
Copying the data set from the permanent memory to the
operating parameter data set
'30'
Copying the operating parameter data set to the perma-
nent parameter set memory
'20'
Copying the default parameters to the permanent memory
and to the main memory
'PS=<aa>'
<aa>
Status acknowledgement, unit [dimensionless]
'00'
Ok
'01'
Syntax error
'02'
Impermissible command length
'03'
Reserved
'04'
Reserved
'05'
Reserved
'06'
Impermissible combination, source type - target type
i
BCL 500
'PC'
i
\ BCL 501