To Perform Transforms Or Filters On An Arithmetic Operation; To Adjust The Math Waveform Scale And Offset; Units For Math Waveforms - Keysight Technologies InfiniiVision 2000 X Series User Manual

Table of Contents

Advertisement

To perform transforms or filters on an arithmetic operation

To perform a transform function (see
"Math Filters"
1 Press the Function softkey and select g(t): Internal.
2 Use the Operator, Source 1, and Source 2 softkeys to set up an arithmetic
3 Press the Function softkey and select f(t): Displayed.
4 Use the Operator softkey to select a transform function or filter.
5 Press the Source 1 softkey and select g(t) as the source. Note that g(t) is only

To adjust the math waveform scale and offset

1 Make sure the multiplexed scale and position knobs to the right of the [Math]
2 Use the multiplexed scale and position knobs just to the right of the [Math] key
Math Scale and Offset are Set Automatically
NOTE
Any time the currently displayed math function definition is changed, the function is
automatically scaled for optimum vertical scale and offset. If you manually set scale and offset
for a function, select a new function, then select the original function, the original function will
be automatically rescaled.
See Also

Units for Math Waveforms

Units for each input channel can be set to Volts or Amps using the Units softkey in
the channel's Probe Menu. Units for math function waveforms are:
Keysight InfiniiVision 2000 X-Series Oscilloscopes User's Guide
on page 90) on the add, subtract, or multiply arithmetic operations:
operation.
available when you select a transform function in the previous step.
key are selected for the math waveform.
If the arrow to the left of the [Math] key is not illuminated, press the key.
to re-size and re-position the math waveform.

"Units for Math Waveforms"

"Math Transforms"
on page 71
Math Waveforms
on page 74) or filter (see
4
71