Can Triggering - Keysight Technologies InfiniiVision 2000 X Series User Manual

Table of Contents

Advertisement

CAN Triggering

To set up the oscilloscope to capture a CAN signal, see
Signals"
The Controller Area Network (CAN) trigger allows triggering on CAN version 2.0A
and 2.0B signals.
A CAN message frame in CAN_L signal type is shown below:
After setting up the oscilloscope to capture a CAN signal:
1 Press [Trigger].
2 In the Trigger Menu, press the Trigger softkey; then, turn the Entry knob to
Keysight InfiniiVision 2000 X-Series Oscilloscopes User's Guide
Differential (H-L) — The CAN differential bus signals connected to an analog
source channel using a differential probe. Connect the probe's positive lead
to the dominant-high CAN signal (CAN_H) and connect the negative lead to
the dominant-low CAN signal (CAN_L).
Dominant low signals:
Rx — The Receive signal from the CAN bus transceiver.
Tx — The Transmit signal from the CAN bus transceiver.
CAN_L — The actual CAN_L differential bus signal.
Differential (L-H) — The CAN differential bus signals connected to an analog
source channel using a differential probe. Connect the probe's positive lead
to the dominant-low CAN signal (CAN_L) and connect the negative lead to
the dominant-high CAN signal (CAN_H).
on page 327.
Bus
Arbitration
Control
Idle
Field
Field
SOF edge
select the serial slot (Serial 1) on which the CAN signal is being decoded.
CAN/LIN Triggering and Serial Decode
Data
CRC
ACK
EOF
Field
Field
Field
"Setup for CAN
Intermission
23
329

Hide quick links:

Advertisement

Table of Contents
loading