Theory of Operation

This section provides a general description of the U3020AS62 Test Set, followed by a more
detailed operating theory. The operation of each component group is briefly described to the
assembly level only.
If you need to disassemble the instrument, be sure to work at an anti-static
workstation and use a grounded wrist strap to prevent damage from electrostatic
discharge (ESD). See

Test Set System Operation

Figure 10
illustrates the components and interconnects of the Test Set. The main function of this
Test Set is Dual Channel Signal Distribution. The Test Set consists of six main components: a
controller module, a 39495EXT module, distribution board for RF switches, two SP6T RF
switches and a front panel LED indicator. There are no adjustments required for the Keysight
U3020AS62 Test Set.
Figure 10
Test Set Block Diagram
L4490A
Front Panel
ATTN
LAN
PWR
Stdby
Dist. Bd
SW A
Input Ports --
1
2
Channel A
Keysight U3020AS62 User's and Service Guide
"Electrostatic Discharge Protection" on page
Switch / Atten
Controller Module
and
Power Supply
I/O
J1
Port LEDs
I/O
J2
(Frt Pnl)
C
3
4
5
6
34945EXT
Distribution Bd
Y1151A
Bank 1
Driver
P101
SW
A
SW B
C
A
---OUT---
B
6
5
Channel
Service Information
24.
P102
SW
B
-- Input Ports
4
3
2
1