Selection and operation of modes

The MELSEC-FX list editor has four modes: READ, WRITE, INSERT, and DELETE.
Select an appropriate mode for the intended operation.
For more information on the mode to select, refer to the function operations from subsection 15.3.8.
How to change modes
Touch the MODE button.
Each time you touch this button, the mode changes.
Touch the
In the case the mode cannot be changed
In the following cases, the mode can be changed to the READ mode only.
If you try to change to other than READ mode, an error message is displayed.
To change to other than READ mode, take the action below.
Error message
PLC is running
Can not write.
28 GOT SELF CHECK (DEBUG)
356
28.2 FX List Editor
button.
The current mode is displayed.
Cause
The FX PLC is in the RUN status.
The protect switch of the EEPROM memory cassette is on.
The EPROM memory cassette is enabled.
Corrective action
Stop the FX PLC.
Switch off the protect switch of the EEPROM memory
cassette.
Set a memory other than EPROM as the memory to write to.