Appendix 9.6.4 Selection of stabilized power supply

Consider the following characteristics when selecting the stabilized power supply (prepared by user).
Use a power supply that complies with CE Marking or that follows the Safety Standards given below.
Stabilized power supply selection items
Item
Output
Output current
Output holding time
Standards
Safety Standards
Noise Terminal Voltage
High Harmonics Current Restrictions : IEC1000-3-2
APPENDIX 9 EMC INSTALLATION GUIDELINES
Appendix 9.6 Parts for EMC Countermeasures
Voltage fluctuation
Ripple noise
Max. 120mV
Spike noise
Max. 500mV
Min. 20ms
: UL1950, CSA C22.2 No. 234 approved, IEC950 compliant
: FCC Class A, VCCI-1 Class
I - 119
Get other manuals https://www.bkmanuals.com
Conditions
±5%
±5% or less of 24VDC output
±5% or less of 24VDC output
Refer to the Connection Manual and
calculate.
Instantaneous OFF time