HEIDENHAIN TNC 620 User Manual page 328

Klartext programming
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

9
Parameters
Tool measurement with the BLUM laser
Q190
Reserved
Q191
Reserved
Q192
Reserved
Q193
Reserved
Parameters
Reserved for internal use
Q195
Marker for cycles
Q196
Marker for cycles
Q197
Marker for cycles (machining patterns)
Q198
Number of the last active measuring cycle
Parameter
Status of tool measurement with TT
value
Q199 = 0.0
Tool is within the tolerance.
Q199 = 1.0
Tool is worn (LTOL/RTOL is exceeded)
Q199 = 2.0
Tool is broken (LBREAK/RBREAK is exceeded)
Measurement results from touch probe cycles 14xx
Parameters
Measured actual values
Q950
1st position in the main axis
Q951
1st position in the secondary axis
Q952
1st position in the tool axis
Q953
2nd position in the main axis
Q954
2nd position in the secondary axis
Q955
2nd position in the tool axis
Q956
3rd position in the main axis
Q957
3rd position in the secondary axis
Q958
3rd position in the tool axis
Q961
Spatial angle SPA in the WPL-CS
Q962
Spatial angle SPB in the WPL-CS
Q963
Spatial angle SPC in the WPL-CS
Q964
Angle of rotation in the I-CS
Q965
Angle of rotation in the coordinate system of the
rotary table
Q966
First diameter
Q967
Second diameter
328
Programming Q parameters | Preassigned Q parameters
HEIDENHAIN | TNC 620 | Klartext Programming User's Manual | 01/2022

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 620 eTnc 620 programming station

Table of Contents