9
Reading system data
With the function SYSSTR you can read system data and store them
in string parameters. You select the system data through a group
number (ID) and a number.
Entering IDX and DAT is not required.
Group name, ID no.
Program information, 10010
Channel data, 10025
Values programmed in the tool
call, 10060
Current system time, 10321
Touch-probe data, 10350
Data for pallet machining, 10510
NC software version, 10630
316
Number
Meaning
1
Path of the current main program or pallet program
2
Path of the NC program shown in the block display
3
Path of the cycle selected with CYCL DEF 12 PGM
CALL
10
Path of the NC program selected with SEL PGM
1
Channel name
1
Tool name
1 to 16, 20
50
Probe type of the active touch probe TS
70
Probe type of the active touch probe TT
73
Key name of the active touch probe TT from MP
activeTT
1
Name of the pallet being machined
2
Path of the selected pallet table
10
Version identifier of the NC software version
HEIDENHAIN | TNC 620 | Klartext Programming User's Manual | 01/2022
Programming Q parameters | String parameters
1: DD.MM.YYYY hh:mm:ss
2 and 16: DD.MM.YYYY hh:mm
3: DD.MM.YY hh:mm
4: YYYY-MM-DD hh:mm:ss
5 and 6: YYYY-MM-DD hh:mm
7: YY-MM-DD hh:mm
8 and 9: DD.MM.YYYY
10: D.MM.YY
11: YYYY-MM-DD
12: YY-MM-DD
13 and 14: hh:mm:ss
15: hh:mm
20: XX
"XX" stands for the two-digit number of the current
calendar week that—in accordance with ISO 8601 —
is characterized by the following:
It comprises seven days
It begins with Monday
It is numbered sequentially
The first calendar week (week 01) is the week
with the first Thursday of the Gregorian year.