Special functions | Lift off tool at NC stop: FUNCTION LIFTOFF
Resetting the lift-off function
Example
18 FUNCTION LIFTOFF RESET
Use FUNCTION LIFTOFF RESET to reset the lift-off function.
Proceed as follows for the definition:
Show the soft-key row with special functions
Press the PROGRAM FUNCTIONS soft key
Press the FUNCTION LIFTOFF soft key
Press the LIFTOFF RESET soft key
The control uses the M149 function to deactivate the
FUNCTION LIFTOFF function without resetting the lift-off
direction. If you program M148, the control will activate
the automatic lift-off of the tool in the lift-off direction
defined by the FUNCTION LIFTOFF function.
The control automatically resets the FUNCTION LIFTOFF
function at the end of a program.
HEIDENHAIN | TNC 620 | Klartext Programming User's Manual | 01/2022
10
427